Safe Wires & Cables CAT 5e/6 Cables


Safe Wires & Cables CAT 5e/6 Cables

Application:-

Recommended for switchboard and telephone wiring in residentials and commercial infrastructure, for transmission of analog and digital signals, wiring in faxes, modems, alarm enunciators, data recording/acquisition systems and various communication devices.

Specifications:-

Performance : Safe Wires & Cables enhanced CAT 6 UTP capable of handling 100 + Mbps data rates. Safe Wires & Cables CAT 5e UTP is independently verified to exceed the requirements of EN50173, ISO/IEC11801 and TIA/EIA568-B-1/B-2.

Cable Construction:-

Conductor : Solid bare copper
Insulation : High density polyethylene
Pair : 2 Insulated conductors twisted together
Outer Jacket : FR PVC
Packing : Available in easy pull box of 100 mtr. and 305 mtr. for CAT 5e and CAT 6 is available only in 305 mtr. pack

Safe Wires & Cables CAT 5e/6 Cables

1 Pair : White – orange stripe and orange
2 Pair : White – green stripe and green
3 Pair : White – blue stripe and blue
4 Pair : White – brown stripe and brown


Mechanical and Environmental Properties
Max. Tensile Load : 10 Kgs. per simplex cable (Installation)
Min. Bend Radius : 8 x Outer Diameter (Installation) 4 x Outer Diameter (Operation)
Temp. – Installation : 0OC to +50OC
Temp. – Operation : -10OC to +60OC

Applicable International Standards for Cable Construction
ISO/IEC 11801:2002
ISO/IEC 61156-5
EN 50173 -1:2002
EN 50288-3-1
ANSI/TIA/EIA 568B-2:2002
Electrical Characteristics at 20OC Specification Typical Performance
CAT 5e CAT 6
Conductor loop resistance Max. 190/100m 160/100m 140/100m
Conductor resistance unbalance Max. 2% 0.5% 0.5%
Dielectric strength 1.0 kV DC or 0.7 kV AC for 1 min. 100% in process test 100% in process test
Insulation resistance >500MΩ/Kmat100-500Vtestvoltage >500 MΩ/Km >500 MΩ/Km
Capacitance unbalance to earth Max. 160 pF/100m 40 pF/100m 40 pF/100m
Velocity of propagation <534 nsec/100m at 100MHz 496 nsec/100m at 100 MHz (NVP for hand held testers = 0.69) 490 nsec/100m at 100 MHz (NVP for hand held testers = 0.69)
Skew Max. 40 nsec/100m at 100MHz Max. 25 nsec/100m at 100 MHz Max. 30 nsec/100m at 100 MHz
Mean characteristic impedance 1000 ±50 at 100 MHZ 1000 ±30 at 100 MHZ 1000 ±30 at 100 MHZ
Coupling attenuation up to 1 Ghz Min. 40 dB 50 dB 56 dB
Frequency (MHz) 1 4 10 16 20 31.25 62.5 100 155 200 300
Insertion Loss (dB/100m) Spec value 2.0 4.1 6.5 8.2 9.3 11.7 17.0 22.0 N/A N/A N/A
Typical value 1.8 3.6 5.8 7.4 8.3 10.5 15.3 19.8 25.4 29.4 33.4
NEXT (dB) Spec value 65.3 56.3 50.3 47.3 45.8 42.9 38.4 35.4 N/A N/A N/A
Typical value 73.3 64.3 58.3 55.2 53.8 50.9 46.4 43.3 40.4 38.8 37.3
PSNEXT (dB) Spec value 62.3 53.3 47.3 44.2 42.8 39.9 35.4 32.3 N/A N/A N/A
Typical value 71.3 62.3 56.3 53.2 51.8 48.9 44.4 41.3 38.4 36.8 35.3
ELFEXT (dB/100m) Spec value 63.8 51.8 43.8 39.7 37.8 33.9 27.9 23.8 N/A N/A N/A
Typical value 78.8 66.8 58.8 54.7 52.8 48.9 42.9 38.4 35.0 32.8 31.5
PSELFEXT (db/100m) Spec value 60.8 48.8 40.8 36.7 34.8 30.9 24.9 20.8 N/A N/A N/A
Typical value 76.8 64.8 56.8 52.7 50.8 46.9 40.9 36.8 33.0 30.8 29.5
Return Loss (dB/100m) Spec value N/A 23.1 25.0 25.0 25.0 23.6 21.5 20.1 N/A N/A N/A
Typical value 25.0 28.0 30.0 30.0 30.0 38.6 26.5 25.1 23.8 23.0 22.8
ACR (dB/100m) Typical value 71.5 60.7 52.5 47.8 45.5 40.4 31.1 23.5 15.0 9.4 3.1
PSACR (dB/100m) Typical value 69.5 58.7 50.5 45.8 43.5 38.4 29.1 21.5 13.0 7.4 2.0
Applicable International Standards for Cable Construction
ISO/IEC 11801:2002
ISO/IEC 61156-5
EN 50173 -1:2002
EN 50288-3-1
ANSI/TIA/EIA 568B-2:2002